I'v been using Hierarchical Schematic Design. In my design, there were 76 nets as shown below:
here is my Design Rule Checker:
But when I run DRC(Design Rule Check) while I left all the connections as shown below:
DRC didn't check for all the nets, only 22 nets was checked:
Whyyy? Did I miss something? Or when I'm using Hierarchical Schematic Design i need to enable something??, Because i can not check for all my net connections after i finish.
Any help would be appreciated!!!
Best Answer
There is an upper limit of 500 errors (in total) reported. Which errors are reported or not seems to be quite random if this limit is exceeded.
You can change the default value in Tools -> Design Rule Check -> "Stop when X violations are found"