Electronic – DPDT rating combined

automotivedpdtloadmaximum-ratingsswitches

https://www.utvinc.com/switches/utv-inc-back-lit-dual-blue-dpdt-on-off-on-vertical-turn-signal-switch/

I want to use a few of the switches in the link above. They are double pole double throw and rated at 20 amps. I want to know if that is 20 amps on one side or 20 amps combined.

I want to run 12V electric fan override by flipping the switch to lets just say the up position.

I am thinking if they are 20 amps on one side I can wire both poles separately, run that wiring into two 25amp fuses and then combine the wiring at a 40 amp relay to send 40 amps continuous to the fan.

Unless they are 20amps combined then my plan will not work and I will be overloading the switch.

If I use two of the DPDT poles can I increase my maximum current rating?enter image description here
OK I was thinking of it backwards. Above is how I am going to wire the switch using it as a ground interrupt.
Thank you for all the help.

Best Answer

Ratings like that are usually per contact.

However, that doesn't mean you can combine two 20 A contacts in parallel to get a 40 A switch. You can not count on mechanical contacts to share current equally. You especially can't count on them to open and close, including all the bounces, at the same time.

Imagine what happens when two switches in parallel open, particularly with a inductive load. One will inevitably open first. Since the other is still closed, the voltage will be low, no arc will form, and that switch will open even with a very small air gap. Now 100 µs later, the other switch starts to open. At this point all the current is going thru it. It will arc when the contacts first separate, but will continue to arc much longer than intended due to the high current.

Most of the wear on mechanical switches is when they open. Closing also causes some stress. Paralleling multiple switches isn't guaranteed to reduce these stresses on any one switch.

If you want to switch 25 A, use a 25 A switch. Or, control a relay or transistor with a smaller switch, with the relay or transistor rated for the full current.

Related Topic