Electronic – How is an AC signal offset

mains

In three-phase the 2nd and 3rd phase are offset by about 120 degrees(\$\frac{2\pi}{3}\$ radians). But how is this achieved?

The concept that just each phase is offset by 120 degrees sounds easy but designing a circuit for this looks more difficult.

Does it go back to when the electricity is generated at the power station or done later on in the transmission?

For example each generator is configured to generate one phase slightly later than another?

Best Answer

There are 3 phase alternators that produce a 3 phase supply which is then transmitted over 3 or 4 wire systems.One first needs to understand how a single phase voltage is generated based on Faraday's laws of electromagnetic induction.The generated voltage is, among other things, also dependent on the (sine of the) angle between the magnetic field and the coil in which the voltage is induced.Now in a 3 phase generator, the the magnets and the coils are aligned (mechanically) in such a way that the angles are 120 degrees apart.Consequently, the instantaneous voltage of each phase offsets the other phases by 2π/3 radians.