Electronic – Is “humming” normal in an AC relay

relay

I have a 240V relay that uses a 120VAC coil. When I switch power to the coil, the relay makes a faint humming sound. It isn't very loud, and sounds like a transformer almost. A normal speaking voice or small fan in the room is enough to drown it out, to give you an idea of the volume.

To be clear, this isn't a situation where the coil isn't getting enough power and contacts open and close rapidly (described as "buzz" in other questions). I have verified that the voltage is correct, and I have observed that the armature is still (not vibrating) when the coil is getting power.

So I am wondering if I have a bad relay, or if this is normal for AC relays, which I haven't used before. I am used to 12VDC relays for the record.

Best Answer

enter image description here

Figure 1. Source: Machine Design.

The relay coil, when energised, pulls in the armature to actuate the contacts. Since the coil is powered by alternating current the magnetic field collapses to zero at each mains crossing and the armature tends to start to release. Its inertia is high enough that the contacts remain actuated long enough to maintain contact through each zero-cross of the mains.

The buzz is normal. It is caused by the vibration of the armature on the yoke on each half cycle.

Just a note on relay terminology: "I have a 240V relay that uses a 120VAC coil" is a little confusing. "I have a relay with 240 V contacts and a 120 V AC coil" would be clearer.


Update:

Spehro and Tony's answers both address the use of 'shading' poles on the armature to help maintain force during zero-cross. This in turn will reduce the vibration.

enter image description here

Figure 2. The yoke of an AC 'contactor' (high-powered relay generally used for AC motor circuits, etc.) showing two shaded poles. Image source.