I'd like to build the circuit detailed here, which calls for a 12V DC 260Ω resistance relay:
Looking at some relays, what consequence would using a 400Ω relay have? Would I be able to use one without a problem?
Unrelated: I believe it's a non-latching SPST NO relay that I need here, right? From what I understand, a SPDT can function as a SPST by ignoring one of the pins; is this correct?
Best Answer
The 400 ohm relay will stay closed longer. You should reduce the capacitor by about 260/400, so about 220uF in order to make the time similar.
Yes, you can just ignore the normally closed contact.