Electronic – Why does this transformer draw so much current

currentmainstransformer

I've been working on a DC power supply to provide about 10 mA at 200 V. The simplest way (not dealing with a switching power supply) seemed to be using a transformer to step 120Vac up a little bit to get peaks near the target voltage, then rectify and filter.

I've wound a custom transformer with a 18:19 ratio to do the step-up which behaves reasonably in simulation, but draws much more current than I expect when actually constructed:

schematic

simulate this circuit – Schematic created using CircuitLab

R2 is an NTC with \$R_{25\mathrm{C}}\$ of 50 Ohms to limit inrush current, and there's a fuse inline (not pictured). When connected the circuit draws upwards of 10A, but it takes a moment to warm up (quite literally; the NTC gets warm as you'd expect) before blowing the protection fuse, to the point where a 4A fuse took more than a second to blow (so current doesn't seem to be dropping after the first few AC cycles).

Since this is a custom transformer I don't have any solid numbers on its characteristics, so it's possible inrush current is much higher than the simulations say. Additionally, I may have underestimated the NTC so it warms up long before the transformer reaches saturation. (The third option being that I'm completely wrong and this is a bad idea.)


How can I limit the primary current to something in the the 1-2A range that I expect from simulation, or is there a smarter way to build this power supply?

Best Answer

When connected the circuit draws upwards of 10A

I'm not surprised. Consider the transformer primary as an inductor and forget about the secondary or any loading. The primary is still an inductor and you have to get the primary inductance high enough so that the current taken (with no secondary winding/load) is reasonably small.

Primary inductance (in fact it's called magnetization inductance) is proportional to turns squared so doubling the turns makes the inductance 4 times greater and, would reduce the intake of current by 4.

Eighteen turns is never going to be enough. A typical ferrite core (for example) might have an A\$_L\$ value of 10 micro henries per squared turn and this means 18 turns is going to be about 3 milli henries. At 60 Hz this has an impedance of just over an ohm and without a fuse you'd have a fire.

Usually AC transformers have round about 1000 turns on the primary and this of course means a primary inductance of 10 henries and a very much reduced magnetization current. Try looking at this site for some information on transformers.

Also note that transformers do not pass DC because the primary inductance becomes a short i.e. the lower the operating frequency you use the more turns you need to avoid excessive primary (only) current.

If you are still intent on rolling your own, here's the math: -

enter image description here

Also take a look at this medium power transformer: -

enter image description here

Note the number of primary turns. A quick estimation I did tells me there are about 12 layers of about 90 turns each. That's 1080 turns!