I'm really new to Proteus, so if I'm doing something very wrong, sorry.

I'm messing around with the Proteus simulation but I don't understand why my voltmeter has given me a value when the circuit is open. I expected it to give a 0 V result. I tried adding a ground to the negative connection of the Voltage source but it didn't help.

Here is my circuit, with the simulation running:

Circuit with a voltmeter connected to a switch and a voltmeter

Best Answer

I think that's what we call "floating": as long as that wire is connected to nothing, you can't know what happens.

It's quite realistic: if you turn on a multimeter and don't connect the Plus-Pin anywhere, it will show values.

Multimeter showing a voltage with Plus-Pin not connected

To get around this, you can ensure that this wire is never connected to nothing by adding a resistor in parallel to the meter:

schematic

simulate this circuit – Schematic created using CircuitLab