Electrical – When using the K155ID1 IC, some numbers of Nixie tubes do not emit properly

nixie

I'm beginner of electronics. (Please understand that I have used Google Translator.)
I connected the IN-14 Nixie tube to the K155ID1 IC. But the numbers in the Nixie tube do not completely emit. When MPSA42 transistor is used, even the higher current limiting resistor normaly emits light, but now it does not emit light completely even when the resistance of the current limiting resistor's value is lowered. Strangely enough, however, the number 6 was completely luminescent.
6 - fully illuminated
0 - Does not emit light completely
4 - Does not emit light completely
And here's the circuit diagram.
circuit diagram
I connected the cathode of each Nixie tube to each pin of K155ID1, and the BCD input was operated by a switch that connected a 4.7k pullup resistor. The Nixie tube was powered by about 180VDC.
Please tell me how to make the Nixie tube digit flash perfectly.

Best Answer

Try anode resistor 33 - 18 -15 - 10K k155ID1 internal zener diode 60v, pull-up resistor connected +5v is 15 - 33K.

Kathode (digit ) 'poisoning' - when highter currentt it shine well. Change back to 27 -33K when OK.