those who are much cleverer than me please help me with this.. Which sensor would be best suited for measuring the intensity of in and out of a person's breathing at rest when the sensor is to be positioned under his nose?
Electronic – Best sensor for breathing activity
sensor
Related Solutions
Your primary criteria appear to be the following:
- Reasonably high throughput (for sending camera capture data)
- 802.15.4/Zigbee specification
- Flexibility in various aspects, including interfacing with sensors and/or Arduino
Based on those criteria, the Xbee Series 1 (802.15.4) and Xbee Series 2 (ZigBee) would be strong candidates for your project.
These modules are available in pin-to-pin-compatible high- and low-transmission-power variants (i.e., longer range and shorter range, but also higher power consumption and lower power consumption). They have an on-board MCU and thus allow direct interfacing with sensors via I/O pins, or alternatively UART interfacing with an external microcontroller.
Depending on what your project cost goals are, you may want to keep in mind that Xbee modules cost $20-$35 depending on which model. They are fairly large in size, with a 20-pin 2.0mm-header form; this form does have the advantage of allowing you to adapt your PCB/design without further modification in case you decide to do a future replacement with similar form-factor modules (e.g., RN-XV for 802.11 Wi-fi, or Bluetooth Bee for BT communicaition).
If you choose to use these modules, they are extensively documented across project pages and forums in the Arduino and other similar communities, however, a good starting point would be Rob Faludi's book. If you are using Arduino's variant of C, or Java, as your development medium, there are the popular (xbee-arduino)[http://code.google.com/p/xbee-api/] and (xbee-api)[http://code.google.com/p/xbee-arduino/] libraries created by Andrew Rapp.
You mentioned air quality data and camera image data as examples of payloads you will be transmitting. Here are corresponding examples for air quality data transmission and camera image data transmission using Xbee modules: (1) Air quality data and (2) Camera image data
Note that the Xbee units do have some disadvantages; here are some alternative suggestions for your project based on each disadvantage:
Large size/Cost: If Xbee unit dimensions or per-unit price are too large, you may want to consider a smaller-scale SMD alternative, e.g., the Atmel Zigbit or TI's CC2530
Large power consumption: If the Xbee units' current draw (ranging by scenario from 50 mA to 250 mA) is too high, then although you stated that 802.15.4/Zigbee is your chosen protocol, you may want to consider newer, more power-efficient alternatives such as Bluetooth LE, for example the BLE112
A simple sensor used in such an application is a magnetic reed switch.
(source)
The simplest normally-open reed switch has two contacts, which are separated when there is no strong magnetic field incident on the switch. When the switch is exposed to a strong enough magnetic field, the contacts close and a circuit can be established through it. In your case, the float would have a small magnet on it, which passes close to the reed switch when the float moves.
The advantage of this approach is that no current flows, and hence no power is consumed, while the switch is open. Power requirement of the sensor is marginal even when the switch is off - just sufficient to overcome a pull-up resistor at the microcontroller sense pin, for instance.
simulate this circuit – Schematic created using CircuitLab
Best Answer
Probably a thermistor to look at the temperature change between inhaled and exhaled breath would be easiest. If you're really interested in flow, then a thermistor in self-heating mode to be cooled by inhales and exhales. the latter is trickier, as inhaled and exhaled breath will be two different temps, so the flow sensitivity for each phase will probably be different.
Moving up the line, you can also look at chest inflation using skin plethysmography, which is essentially the broadcasting of a small sin wave, and looking at the reception at a distant location on the chest. The sine wave should really be isolated.