Often I will see a ferrite bead a couple of inches from one end of a cable. Does the position of a ferrite bead really matter?
Ferrite Bead – Does Position Matter on Cables?
cablesferrite-bead
Related Topic
- Ferrite Bead – How Much Impedance is Needed?
- Electrical – Ferrite bead for mobile headset
- USB MIDI Ferrite Bead – Ferrite Bead in Cable or in Device?
- Electronic – Should ferrite beads be closer to the stepper motor or to the motor driver
- Electronic – the purpose of the ferrite bead on DC Adaptors
- Electronic – Ferrite bead attenuation frequency
Best Answer
My answer hopefully applies to beads but also ferrite clamps on cables.
If it's preventing susceptibility problems due to interference coming down a cable then its position is not that critical. However, if it's stopping emissions getting out from a device, a better position is as close to the interfering source as possible. There is every chance that interference getting onto a cable (such as from a switched mode power converter) can radiate from the cable so, best to keep the ferrite up as close to the source of noise as much as possible.