I sort of have an answer but it may not be one that you like.
I have the same problem in a mobile audio recording truck that I am working on. The person with whom I am working has tried every combination of every single LED fixture and wall-mount dimmer that was available locally as well as several units purchased online.
All of these have some degree of flicker at the low end of lighting.
My solution is sort of drastic. I'm going to rip the electronics out of every LED fixture in the control room and install a very-fast-acting PWM constant-current driver inside each fixture. Then I'm going to use one of the standard PWM LED dimmers that we build and simply supply 12V PWM to each fixture.
I have the freedom to do this - I was worried that flicker might be a problem (past experience) and made sure when wiring the control room that I would be able to isolate those particular lighting runs from the 120 Vac supply and instead use DC.
My particular case is fairly unique in that I have several hundred Amp Hours worth of 12V battery in the truck's battery compartment from which to draw power. You would have to find somewhere to install your DC power supply, whatever voltage you want to use.
I have two standard LED PWM frequencies that I use: 977 Hz (1024 us tick rate) & 4 KHz. Both work well and I have never experienced a flicker problem with either. I'll probably wind up using the 977 Hz version just to give the constant-current LED drivers a fighting chance of working well.
Apart from what Brian says, which may very valid in some cases, there are also other options for why this happens:
- The IR sensor hasn't got a relay but solid state switches: Solid state switches can always leak a tiny amount of current. This is why solid-state switch or dim packs in lighting rigs for shows need to be un-powered before people are allowed to modify cabling, as the leakage a "turned off" >10A triac can give, especially when aged a little can be dangerous or lethal in some cases. Depending on the design and Q.A. of the IR sensor the difference in leakage between one and another can be quite large.
- The sensor showing the problem has more contamination/dirt on the inside, due to wind or rain or even due to sunshine degrading the plastic joints letting water and dirt in over time. This then creates creeping current between the switch contacts.
- The IR sensor has a snubbering circuit that creates a leakage capacitance across contacts, which acts the same as the wire capacitance Brian mentions: A capacitor at AC (changing current directions) becomes a sort of resistance to the current flow, and thus allows a little leakage current through.
- One of the switches in the system has a NEON pilot light, either hidden or still visible, which leaks a few mA of current through the load lamp.
A pilot light is connected like this, for reference:
simulate this circuit – Schematic created using CircuitLab
With an incandescent lamp, when the switch is open, you can see that the 250 Ohm of the lamp does not add much to the 30kOhm already in the loop, so the neon light will turn on, and only 1 to 2mA will go through your ceiling light, which will not turn it on at all, won't even get warm, as across the 250 Ohm it presents 2mA is only 0.5V, way too little for a 115V lamp to turn on.
Now a leaking Triac will also be in the range of 2mA to 10mA, so will most capacitive coupling. Creep (before other paths will trigger earth faults that should cause a power shut off) usually stays under 50mA. All of those current are much too low to cause any noticeable effect in the wire of the incandescent.
But what happens when that current goes through a LED bulb? Well, a modern CFL or LED bulb usually has very low, to nearly zero internal leakage, so then the internal circuitry can be seen as this (they are much more complicated if well designed, but for this purpose, this is the representation):
simulate this circuit
When you have a hard switch, all is well, switch on: Light on. Switch off, light off.
Now, what happens if you have something "pumping 5mA" into the lamp continuously? 5mA is still not enough to power the LED, right, so... That should not turn it on at all, 5mA is only 500mW, and your LED bulb is, let's say 10W, so the maths is clear.
Well, because there is no leakage, the 5mA will just charge the capacitor. If we assume the current to be perfectly constant (not entirely true, but close enough), it will charge up over time like this:
dV = (dt * I) / C
with C = capacity of the capacitor, I is the constant current, and dt is the time period, and dV is the change in voltage.
At some point the capacitor charges to the turn-on voltage of the controller, and the LED will turn on, using the energy in the capacitor. Because your bulb drains the energy in the capacitor much quicker than the current can replenish it it will drop to the turn-off voltage and turn off.
Depending on the size of the capacitor and the turn-on and turn-off voltages of the controller, the flickering can be quick, slow, or even so quick that it looks like an always-on bulb that flickers in brightness.
These flickering speeds also get influenced by the number of bulbs connected.
Funny thing is, that based on the flickering pattern of 3 or more lamps connected to one system it is possible to make some assumptions about what might be the cause. While no guarantee, it has some basis in analysis that is valid.
If they all flicker in an nearly synchronous pattern, the leakage current is highly voltage dependant, whereas if they flicker less in sync the leakage current is more constant, and this may give hints about where to seek when there is a full scope of the entire system.
As a side note: If the flickering is a real "fluid" flickering in an on-state it may be that the LED controller leaks the current through into the LEDs without actually turning on and the flickering is caused by much smaller on/off margins and inferring anything from a pattern is much harder.
Will this energy also leak away if there are incandescents? Yes! As I showed you above, the current flows, you just don't see it. So in a way with the LED lights you're already winning, if you can get past the flicker annoyance, because now at least the leakage is doing something for you.
The reason the flickering stops when you add only one incandescent is basically also already answered: If you add the low-resistance lamp in the loop, the leakage will only cause up to a few volts maximum on the wires, which is way too little for the High-Voltage LED driver to turn on, or to leak into the LEDs themselves.
Best Answer
Based on what I read here, I have just successfully brought my Revo Blik back to life by replacing the backlight LEDs with 2x Bright White 3mm LEDs (£0.84 each from Maplins). A window scraper blade happily cuts the adhesive that holds the LCD/Backlight/PCB together. The LCD folds out by 90deg. The backlight removal was the biggest problem as the two existing LEDs proved very difficult to unsolder. For insertion of the new LEDs I drilled the holes out to 1mm. and used high lead solder (old stock).
With the old diodes removed, the +ve voltage was +5.1V . After the new LEDs were soldered in, the anodes were at +2.24V.
The screen is now fully readable. Thanks to all previous posters for the guidance that led to my success. Bob