I am working with VFD (CT-2002ES-A75). It shows output frequancy on it's seven segment display. However It has a parameter(Cd46 on page 27 in the manual) for display the current RPM of the motor.
For display the current RPM need to enter some factor as parameter input.
How to calculate that scaling factor for my motor?
This is the nameplate of the motor that controlled by the VFD.
Motor is connected as star system. Working on 230VAC supply.
Best Answer
This can be generalised as RPM = 120 x f / poles.
Therefore # of poles = 120 x f / RPM.
Since induction motors slip the full-load RPM will be somewhat less than the calculated speed. From the rating plate we can see that the min -1 (revolutions per minute) is 930 to 950 at 50 Hz. This is just below 1,000 RPM so it must be a six-pole motor.