For a 2-row connector intended to interface a cable to a PCB, which method is preferable for twisted pair LVDS signals?
Horizontal Pairs:
LVDS1- LVDS1+ LVDS2- LVDS2+
Vertical Pairs:
LVDS1- LVDS2-
LVDS1+ LVDS2+
I would have thought the difference would be inconsequential but a PCB designer mentioned that the horizontal configuration offers better signal integrity. We were in a group conference call so I didn't really have an opportunity to ask him to explain himself. Is he correct that horizontal pairs are preferable to vertical pairs?
Best Answer
Low skew and good impedance to gnd for 100 Ohms is desired.
follow this for LVDS applications.
Connectors must have low skew with matched impedance over entire spectrum.
Ground pins should be placed between differential pairs.
-