Electronic – Should I use separate grounds for these voltage regulators

groundvoltage-regulator

I am a bit confused right now.

I have 2 voltage regulation modules:

The 24V-12V has Vin+, Vin-, Vout+, Vout- while the 24V->5V only has Vin, Vout, GND.

Do I have to use a different ground for the Vin- than for the Vout- and if, which one should I choose for the second regulator? If not, why are there different Vin-/Vout- in the first place?

Best Answer

The feature list on the first page of the datasheet for the 24->12 module states "Non-isolated Module". This indicates that the Vin- and Vout- leads are connected together in the module - the input and output have the same ground.