Electronic – The best way to get rid off common mode noise for remote measurement

common-modemeasurement

I measure DC pseudo-differentially over 1-2 m wires. In order to avoid any voltage drop in wires the built in ADC input buffers are used, thus there almost no current flow. I expect the wires to catch a lot of common mode noise from RF to 50 Hz power grid.

Most materials about common mode noise that I found, consider it in the context of power line that involve common-mode chokes. Howver, I am not sure if this is suitable for my measurement.

Another way is the vanilla common mode filter

enter image description here

But again, I am not sure if it would be good enough and provide adequate level of filtering.

Moreover, there might be more methods that I am not aware of.

What possibilities are there to suppress common mode noise, and what is the best method for a measurement application?

In addition, how much the application of a shielded twisted pair cable would help to ease the problem?

Best Answer

You have to take care of two kinds of interference:

  • common mode interference caused by capacitive coupling
  • differential mode interference caused by inductive coupling

Capacitive coupling is already handled well by shielding and by using a differential pair of signals because it affects bouth lines about the same.

For handling inductive coupling using a twisted pair is very important.
If wires are not twisted it is easy to induce quite a large voltage (acting like a AC voltage source in series of the signal source) caused by changing magnetic fields (possible sources are transformers, speakers, SWPS, cellphones... any AC currents). Twisting the differential pair reduces the intereferences as every other twist adds a positive/negative intereference to the signal ideally canceling out at the end (see Image below).

interference by induictive coupling in non-twisted vs. twisted pair wires

  • The upper part shows a non-twisted wire pair: interfernce by induction is large (proportinal to blua area).
  • The lower part shows a twisted wire pair: interference by induction is small (or even zero) as positive (+) and negative (-) interferences cancel out (partially).