Electronic – will snubber pass voltage thourgh it

currentleakage-currentsnubbertriacvoltage

We are doing home automation project. In that we are using triac for ac switching and snubber circuit (R=100ohm, c=10nf) for its protection. Here we have inductive and resistive load, for inductive load there is no problem but in resistive load when we connect less than 5W means it is glowing continuously without switching on. Suppose we remove the snubber for resistive load it's not glowing. so how to reduce that small leakage via snubber. Please suggest me your solution.

Best Answer

Simply set smaller enough capacitance in the snubber or remove it at all.

Notice that the internal capacitance of the triac, together with the high resistance of the load will act as a snubber by itself, preventing high dV/dt on the triac.

The snubber actually does not "protects" the triac, but prevents it by incidentally switched ON because of high dV/dt - mainly when you switch the power ON or on high surges in the power network.

But such wrong switching is a big problem only in a DC powered thyristor circuits. Working in AC, even incidentally opened, the triac will close by itself on the next half period of the power voltage - i.e. after max 10ms. I don't think it is a big problem for the most loads. At least not for resistive, low power loads.