Cisco 2950 switch LED off timeout

ciscopacket-lossswitch

Some random ports led turns off for less than a second https://www.youtube.com/watch?v=eUl4ifveh74
Right in that time i have 2 timeouts in one or more ports which turned off .
why is it doing that?

firmware is up to date . ports are ok and tried with other ports .

show log
Note: The changed states are by hand and normal

00:41:31: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to down
00:41:33: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to up
00:41:50: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to down
00:41:52: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/23, changed state to up
00:42:00: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to down
00:42:02: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to up
00:42:05: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to down
00:42:07: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to up
00:42:22: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to down
00:42:24: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/22, changed state to up
1d03h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/11, changed state to down
1d03h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/17, changed state to down
1d03h: %LINK-3-UPDOWN: Interface FastEthernet0/11, changed state to down
1d03h: %LINK-3-UPDOWN: Interface FastEthernet0/17, changed state to down
1d03h: %LINK-3-UPDOWN: Interface FastEthernet0/17, changed state to up
1d03h: %LINK-3-UPDOWN: Interface FastEthernet0/11, changed state to up
1d03h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/17, changed state to up
1d03h: %LINEPROTO-5-UPDOWN: Line protocol on Interface FastEthernet0/11, changed state to up

show interface

http://paste.ubuntu.com/7541959/

One more thing . Pinging the switch is abnormal . I am far from switch and normal ping should be less than ~10ms . But as you can see the ping goes high decussate

Reply from x.x.x.x: bytes=32 time=8ms TTL=255
Reply from x.x.x.x: bytes=32 time=28ms TTL=255
Reply from x.x.x.x: bytes=32 time=181ms TTL=255
Reply from x.x.x.x: bytes=32 time=14ms TTL=255
Reply from x.x.x.x: bytes=32 time=195ms TTL=255
Reply from x.x.x.x: bytes=32 time=6ms TTL=255
Reply from x.x.x.x: bytes=32 time=215ms TTL=255
Reply from x.x.x.x: bytes=32 time=11ms TTL=255
Reply from x.x.x.x: bytes=32 time=226ms TTL=255
Reply from x.x.x.x: bytes=32 time=10ms TTL=255
Reply from x.x.x.x: bytes=32 time=242ms TTL=255
Reply from x.x.x.x: bytes=32 time=16ms TTL=255
Reply from x.x.x.x: bytes=32 time=255ms TTL=255
Reply from x.x.x.x: bytes=32 time=16ms TTL=255
Reply from x.x.x.x: bytes=32 time=273ms TTL=255
Reply from x.x.x.x: bytes=32 time=19ms TTL=255
Reply from x.x.x.x: bytes=32 time=285ms TTL=255
Reply from x.x.x.x: bytes=32 time=21ms TTL=255
Reply from x.x.x.x: bytes=32 time=298ms TTL=255
Reply from x.x.x.x: bytes=32 time=40ms TTL=255

Best Answer

Looks like a hardware fault. This is not standard nor accepted behavior. I'd agree with Mr. Lock and test your cables. Beyond that, try re-loading the IOS image on the switch. If all of that fails, you might need to replace the switch.