Juniper SSG20, reset to factory default

juniperscreenos

I have an Juniper SSG20 that I have tried to reset to factory default.

I have tried the pin hole reset method but to no avail, and the serial console doesn't indicate that the procedure is started, but the LED is changing to orange but it doesn't get to the Red state.

And login with the serial no as user and password is also failing.

I have opened the firewall and can see a battery soldered to the PCB, is that a solution to desolder the battery? Or is there any other trix?

Best Answer

Request system zeroize is for srx, for ssg use serial number as username & password, it should reset it.

  1. Get your device serial number using the following command (or by reading the label on your device) :
ssg5-serial-wlan-> get system | i serial
Product Name: SSG5-Serial-WLAN
Serial Number: 000000000000000, Control Number: 00000000
Interface serial0/0:
description serial0/0
  1. Then logout and use the serial number as login and password

login: 000000000000000

password: 000000000000000

!!! Lost Password Reset !!! You have initiated a command to reset the device to factory defaults, clearing all current configuration and settings. Would you like to continue? y/[n] y

!! Reconfirm Lost Password Reset !! If you continue, the entire configuration of the device will be erased. In addition, a permanent counter will be incremented to signify that this device has been reset. This is your last chance to cancel this command. If you proceed, the device will return to factory default configuration, which is: System IP: 192.168.1.1; username: netscreen, password: netscreen. Would you like to continue? y/[n] y