Dell PERC 4 (PowerEdge 2850): Unresolved configuration mismatch between disks(s) and NVRAM

bootdelldell-percdell-poweredgehard drive

We had an extended power outage (almost four hours); now I have a Dell PowerEdge 2850 server which is giving me this error (from a PERC 4e/DI) on boot up:

Dell PERC 4e/DI boot messages

All drives are listed in the PERC configuration menu:

Dell PERC 4e/DI Configuration Menu

The failed drive does not show any indications of failure on the LEDs; the bottom appears to be green and the top is unlit. None of the disk drive LEDs are flashing.

All drives are in one RAID5 array with 6 stripes of 64K in size.

I do have one or two spare Dell PE2850s available for test. However, from what I've read, the Unresolved configuration mismatch... error would show up then – but perhaps I could activate the good drives anyway.

What if I remove the bad drive and try to boot that way? I may try that – but both the PERC 4e/DI and the Adaptec 2410SA card (activated later in the boot process) list all ports as not functioning.

Here are the specific questions:

  1. Is it possible to get this (degraded) array running again on this system? How?
  2. Will it help to configure a new configuration and save it (without initializing)?
  3. Is it possible to move a degraded array to a new system and power up?
  4. What if the "bad" disk was removed or replaced? How does that affect the system boot? How does that affect a disk array move?

EDIT: I found this question which appears to detail how to move drives from one host to another; is there anything more that should be added to the process detailed there? In my case, the move would be different in two ways: one, I have an apparently degraded array (RAID5), and two, the array is RAID5 not RAID1. The first is the biggest question mark; RAID5 should import just like RAID1 I'd say.

I found this question which talks about "repairing" a failed mirror, but there is no clear answer on how to fix it, and I'm using a RAID5 anyway – a RAID5 which hasn't been moved or rearranged.

UPDATE: The replacement system has a PERC 4/DC in it – compared to the old system which has a PERC 4e/Di in it. I hope this will recognize the old (degraded) array and import it just fine. If this works well, I'll even be able to use the old drives (no failures there) as a replacement for the failed drive.

Best Answer

Sounds like it's gone slightly nuts and is getting one config from the good drives and another slightly out of sync or invalid config from the "faulty" drive.

First thing I would do is just remove the faulty drive and try booting up then. If that doesn't work, then try with one of your other 2850's.