Dell Poweredge R410 replace PERC S100 with PERC 6i

delldell-poweredgeperc6raid

I want to replace the PERC S100 RAID Controller with a PERC6i to be able to use 4 SAS harddrives instead of only SATA drives. What exactly do I need for this, what I've got so far:

  1. PERC6i PCIe x8 card.
  2. 4 x SAS 300GB 15000rpm drives

Some questions I have

  1. Do I need a different backplane to accomodate the SAS disks? If so, what kind of backplane?
  2. Do I need a special cable to hookup the PERC6i with the backplane? If so, what kind of cable?

Thanks.

Best Answer

I'm not sure the answer above is correct - your question reads that you wish to replace your existing SATA drives with SAS - I'm guessing these are internal so the PERC 6i would be correct rather than PERC6e.

As far as I know, Dell didn't make a SATA specific backplane so there should be no need to change backplane or cables.

You may also wish to look into the PERC H700 controller - this is the newer replacement to the 6i - both are compatible with the R410.