We have a hd damage and we need to replace this hd, How to change and add more hd to array to HP Proliant ML 350 G5 server ?
How to change hard disk array on HP Proliant ML 350
hard drivehphp-smart-arraywindows-server-2008
Related Topic
- BBWC Parts for Proliant DL380 G5 / HP Smart Array P400
- HP Smart Array – How to Determine HP Smart Array Model
- HP ProLiant DL380 G6 server error code: 347 of array controller
- Proliant ML310e Gen8 – Smart Array Predicted Failure with SSD
- How to upgrade the firmware of HP SAS expander card without Smart Array controller or Proliant Server
- HP Proliant – RAID 5 array recovery
- Smart array P410i Maximum hard drive capacity
Best Answer
If you're running Windows 2008 on this system, you will want to use the HP Array Configuration Utility in either its graphical or command-line form. For the purposes of this question, I'd recommend the command line utility.
Once installed, you will want to navigate to your Programs Menu and open the Array Configuration Utility (it may specify "command line").
Once inside the utility, run the following command:
ctrl all show config
This will output something like:
If any of the output indicates failed or pre-failure, that's enough evidence for HP to send a replacement disk.
Once you've verified that there's a bad disk. You can identify the drive with its blue LED indicator. In this case, I would use the following command to identify the drive:
This will blink the drive in question for one hour.
As for the mechanics of drive replacement, you need to identify the disk, press its release lever, open the drive handle, then remove the disk. Installation is done in the reverse order.
If you're interested in adding more disk space to the array, see these questions on Server Fault...
HP RAID array - hpacucli
What are the good ways to migrate a RAID array to bigger disks?
Repurpose spare drive in HP ProLiant RAID 5 array