How to change / replace a failed “system” disk on EMC Clariion CX500

clariiondiskmanagementdrive-failureemcreplace

On the first DAE, the first 5 disks are considered "special" because they host the OS of the storage array.

One of those 5 disks is faulty : what is the procedure to change it?

By the way, what kind of RAID configuration is set up on those?

Best Answer

There are only 4 OS drives. Slots 0, 1, 2, & 3. The OS drives are mirrored. The procedure to replace one is to simply pull the faulted drive and put the new one in. It will automatically start rebuilding and mirror back to that drive. If I remember correctly, drive 0 is mirrored to 2 and 1 is mirrored to 3.