How to clear the REPLACEBATT state from APC UPS after hot-swapping the battery

ups

I replaced a battery in APC SmartUPS by hot-swapping. While the swap was all right and didn't disturb connected computers, the "Battery failed" LED on the front face kept glowing.

I tried to use apctest from apcups package. Turned off the daemon and run self test (first changing BATTDATE in EEPROM). The test run fine but didn't clear the REPLACEBATT status or the glowing LED.

How to clear the failed battery state without powering the UPS and connected equipment down?

Best Answer

To clear this status one needs to run the self test using the Test button on front panel.