How to update X25-E SSD firmware in PowerEdge 2900 with PERC 5/i

dell-poweredgeraidssd

How to update the X25-E SSD firmware in a Dell PowerEdge 2900 with aPERC 5/i RAID controller? In other words, how to make the two SSD's visible to a firmware boot disk as such, when the RAID controller is presenting them as one RAID 1 volume?

Best Answer

I updated the X25-E firmware by temporarily removing each SSD from its drive carrier and Icy Dock adapter, and connecting it as follows:

Data - connect the data interface of the SSD to the onboard SATA-A port of the PE2900 system board using a standard SATA data cable.

Power - connect a Molex-to SATA power cable from a spare Molex connector to the power interface of the SSD.

In BIOS, enable onboard SATA and enable the SATA-A port. Boot to the boot-CD containing the Intel firmware updater.

After the update completes, restore the orignal Icy-Dock, drive carrier, backplane configuration and restart the server.