HP ML115 with P400 Smart Array Controller

hphp-proliantraid

I have a HP ML115 server I have installed a HP P400 Smart Array Controller card, I also have 4 x 1TB Samsung Hard drives.

I'm unable to get the the controller to detect the hard drives, I have changed the drives to SATA 1.5G without luck, I have also tried connecting a single 80GB Maxtor drive without luck

The controller shows up just after boot and tries to initialize, The controller does not show up in the POST prompt, although I can see the controller when booting off a ACU CD

THe controller firmware is a little old v4.12 but I have no way to update it.

Any ideas on how I can get this going?

Best Answer

Fran Garcia is correct, you can't just pick your own SATA disks with those controllers - HERE's the quickspecs to help you choose the correct disk part numbers.