LSI Megaraid alarm – clearing hotspare

lsimegaraidraid

I have several Supermicro servers with LSI Megaraid controllers, 9266-8i. One recently lost a drive; I replaced it as usual, but it is still beeping on reboot. It is set up as RAID 10 + hotspare.

MegaCli64 -AdpEventLog -GetEvents -f events.log -aALL && cat events.log shows me:

Event Description: Global Hot Spare created on PD 08(e0xfc/s0) (global,rev)
Event Description: Reminder: Potential non-optimal configuration due to drive PD
                    08(e0xfc/s0) commissioned as emergency spare

Since the beep pattern is 1 second on, 3 seconds off, which is the code for "SPEAKER_HOTSPARE_ENTRY – A hot spare drive has completed the rebuild process and has been brought into the array", I assume this is the root of the problem. I have updated to the latest firmware, since the release notes mentioned the "Potential non-optimal configuration" message, but no change.

Anyone have an idea on how to clear this?

Best Answer

Source: IBM tip H206526

There is no functional impact. To prevent the message from appearing in the system event logs:

  • Open MegaRAID Storage Manager.
  • Select Tools --> Monitor Configure Alerts.
  • Select Change Individual Events.
  • Highlight event ID 406.
  • Deselect the System log check box.