Ntldr is missing error, is issue scsi/raid boot drive identification

adaptecraidscsiwindows-server-2003

I stopped an ibm x series 266 server to clean it out. It has two scsi drives in raid 1, 36 gb. While I had the drives out for cleaning I started the server to get the fans running, to exhaust dust that was being stirred up.

Now when it boots, after it runs through id'ing the scsi devices it fails to boot with 'ntldr is missing'. This is windows 2003.

When it is scanning for scsi devices it seems to find the 36gb scsi array. My idea is that because it booted without the drives once (or tried to) it somehow lost it's idea of booting from the raid array. I have been into both the main bios and the scsi setup and don't see what to do to fix this. There are two scsi channels (I think they are called, I'm not good with scsi) listed, A and B.

AIC-7902 A at slot 00 03:03:00
AIC-7902 B at slot 00 03:03:01

A only hosts the adapter on ID 7. The other channel B shows two 36gb IBM devices, those would be the hard disks, on ID 0 and 1, the adapter on 7. Both A and B have master scsi controller and boot scsi controller set to B.

Or is it finding the boot device? I don't see an OS not found message, or whatever the equivalent is for windows 2003.

Can someone point me to a config setting that would solve this issue?

Best Answer

So, it's solved.

In the main bios, in startup options, pci device boot priority was set to Planar SCSI. I set it to Slot1, and rebooted. I then set it back to Planar SCSI, and at the next reboot it found the hdd and windows 2003 started normally. Whew!