OOBE not run after sysprep, only a login screen is displayed

sysprepwindows 10

I try to prepare a Windows 10 21H1 installation with sysprep for imaging. I activated OOBE and generalize. Sysprep says that it was successful, but it ran to quick and the log file (setupact.log) ends abrubtly, see below.

The problem is that after a reboot I'm not presented with the OOBE first run setup stuff but just with the login screen for "other user" and I can't login there.

The panther directory has an empty setuperr.log and setupact.log contains two warnings, no errors and a lot of entries like this at the end:

...
2021-08-12 10:07:51, Warning                      TapiSysPrep.dll:RetainTapiLocations:RegQueryValueEx() returned 2
...
2021-08-12 10:08:15, Warning               SYSPRP SPPNP: Failed to configure oem31.inf (fn.inf). Err = 0x430
...
2021-08-12 10:08:19, Info                  SYSPRP SPPNP: Configured oem53.inf (wiman.inf).
2021-08-12 10:08:19, Info                  SYSPRP SPPNP: Configured oem54.inf (qmuxmdm.inf).

Best Answer

Since the warning is about a driver, investigate the driver store with dism /Online /Get-Drivers

Search for oem31.inf and/or fn.inf and try to uninstall that device before sysprep.