Im using a PERC 3/DC controller to run a RAID 5 array using 4 hard disks.
I am hoping to change this to 3 disks in the array and 1 hot spare.
Is it possible to remove 1 disk from the array, reconfigure it as a hot spare, then reconfigure the RAID 5 array to use 3 disks WITHOUT loosing any data?
I have backups but I would rather just reconfigure it without going through the hassle of restoring data.
Thanks!
Remove 1 Disk From 4 Disk RAID 5 Array
hardware-raidraid
Related Topic
- Recover data from PERC 6/i RAID5 array using software RAID
- Replacing a Hard Disk in RAID 5 Array with Newer Version
- Dell PERC6/i – Converting from RAID 5 to RAID 6 – Possible
- Linux – How to keep an offline disk mirror with a PERC 6/i
- CentOS – Monitoring Hard Disk Status with Dell PERC H710 RAID Controller
- RAID Migration – How to Migrate RAID 6 to RAID 5 Without Data Loss Using LSI MegaRAID
- RAID – Optimal Stripe Size for RAID10 in VMware with H730P Mini Raid Controller
Best Answer
No, and if you have 4 disks and want two spares you are better off performance wise with a 4 disk RAID 10 instead of a 3 disk RAID 5 + hot spare. Either way your array will have 2 disks worth of usable capacity but the RAID 10 will have better write speeds and takes less time to recover from a failed disk.
Assuming the RAID 5 doesn't contain your boot volume, I'd go ahead and backup the data, reconfigure to a RAID 10, and restore the data.