Resert IBM system x3650 fault led

diagnosticibm-xseriespower-supply-unit

I got OVERSPEC, PS1 and PS2 fault led on my x3650. I tried to replace one PS but nothing changes. The power supplyp seems to work properly and it is very strange to broke both PS at the same time.
I tried to reset the system log, reboot, but these leds are still on.
What can i do?

Best Answer

Need update - Baseboard Management Controller (BMC) Version 1.44 build ID GFBT60AUS

System machine types 7978 and 1913. Please read - https://delivery04.dhe.ibm.com/sar/CMA/XSA/010ds/0/ibm_fw_bmc_gfbt60a_dos_noarch.txt

Baseboard Management Controller Version 1.44 (Build ID GFBT60AUS) - Suggested Fixes:

  • Fixed the erroneous Power Supply(PS) 2 fault and recovery messages
  • Fixed the problem that sometimes PS LED still on after power re-applied