I have two HP ProLiant DL380 Gen9 servers with Windows Server 2016 on which a SQL Server 2016 is to be installed in the failover cluster with Storage Spaces Direct. When I try to activat S2D via PowerShell I get the error:

WARNING: 2017/07 / 13-10: 13: 48.295 Disk number 2 ({455cd214-ecdd-7e52-b5c5-a505367c878c}, friendly name 'HP LOGICAL VOLUME') on node DB1 has unsupported media type

The HDDs as well as SSDs are set up in a RAID.
The SSDs are recognized as MediaType SSD, but the HDDs are unspecified.
Changing the MediaType via Set-PhysicalDisk -FriendlyName HPLogicalVolume -MediaType HDD failed.

The HDDs and SSDs are online but without a partition and are recognized as Bus Type SAS.

How can I activate Storage Spaces direct in this configuration or where is my error?

Many thanks in advance.

Best Answer

You have to have supported media types with Storage Spaces Direct which is no-RAID, no-FC and no-iSCSI. Should be SATA, SAS and NVMe.

https://docs.microsoft.com/en-us/windows-server/storage/storage-spaces/storage-spaces-direct-hardware-requirements

Drives

Use local-attached SATA, SAS, or NVMe drives.

You can easily workaround this issue if you say don't have compatible SAS HBA and want to use RAID controller and single driver RAID0 nodes by forcing RAID -> SAS using registry tweaking or installing third-party filter driver to do that.

https://www.starwindsoftware.com/blog/resolving-enable-clusters2d-bus-type-support-issue-on-some-storage-controllers

I can't find the driver though...

P.S. In general I'd skip using S2D on only two nodes, it's clumsy at best: fault tolerance isn't great: cluster can't survive second disk or node crash in a row, multi-resilient disks and erasure coding aren't available.