C# – Reg Free COM – Isolating COM Reference – missing value ‘(Default)’

ccomnetvb6

So I have a registration free VB6 DLL referenced by my .NET 3.5 assembly library that's ultimately referenced by a .NET 3.5 WinForms application (not sure it's relevant, but included to paint a picture).

I am getting the error 'Problem isolating COM reference 'SomeVBDll': Registry key 'HKEY_CURRENT_USER\SOFTWARE\CLASSES\CLSID\{dd1d7f58-1d6b-4370-a1b9-05c03816a128}\InProcServer32' is missing value '(Default)'

My initial attempt was to check if this value actually existed and then put it into place. This resulted in the same above message on compilation.

Has anyone encountered this problem and know of any resolution to it?

Thanks in advance. Below is the manifest from the assembly that directly references the VB6 dll.

    <assembly xsi:schemaLocation="urn:schemas-microsoft-com:asm.v1 assembly.adaptive.xsd" manifestVersion="1.0" xmlns:asmv1="urn:schemas-microsoft-com:asm.v1" xmlns:asmv2="urn:schemas-microsoft-com:asm.v2" xmlns:asmv3="urn:schemas-microsoft-com:asm.v3" xmlns:dsig="http://www.w3.org/2000/09/xmldsig#" xmlns:co.v1="urn:schemas-microsoft-com:clickonce.v1" xmlns="urn:schemas-microsoft-com:asm.v1" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
  <assemblyIdentity name="Native.App.Core" version="1.0.0.0" type="win32" />
  <file name="SomeVBDll.dll" asmv2:size="184320">
    <hash xmlns="urn:schemas-microsoft-com:asm.v2">
      <dsig:Transforms>
        <dsig:Transform Algorithm="urn:schemas-microsoft-com:HashTransforms.Identity" />
      </dsig:Transforms>
      <dsig:DigestMethod Algorithm="http://www.w3.org/2000/09/xmldsig#sha1" />
      <dsig:DigestValue>BWWHQTqNGUupT8xznLoN3jn7S9Y=</dsig:DigestValue>
    </hash>
    <typelib tlbid="{755c1df5-d0c5-4e10-a93d-54bf186e8daf}" version="1.0" helpdir="" resourceid="0" flags="HASDISKIMAGE" />
    <comClass clsid="{dd1d7f58-1d6b-4370-a1b9-05c03816a128}" threadingModel="Apartment" tlbid="{755c1df5-d0c5-4e10-a93d-54bf186e8daf}" progid="SomeVBDll.MyClass" />
  </file>
</assembly>

EDIT///

Marking all of the classes within the VB6 DLL as MultiUse seems to have resolved the problem. While this gets around the problem I was experiencing and still allows me to use reg-free COM, does anyone know a way to get around having to set all of the COM classes Instancing to MultiUse?

Best Answer

The only solution I've seen proposed (if you want to avoid the possible security/maintenance issues of marking all classes as MultiUse) is to delete the ".../InProcServer32" registry key, but that workaround comes with the standard "be careful messing with the registry" caveat.