If I have a three terminal TO-220 voltage regulator where the center terminal and heat sink are connected ground terminals, is there any reason not to mount the heat sink directly to an aluminum chassis (with a bit of thermal grease)? I have a device that has an L78S12CV 12 volt regulator mounted to a finned heatsink, which itself is mounted to the chassis. Between the device and the heatsink there is a mica insulator, but the bolt holding the regulator to the heatsink/chassis is not insulated with a nylon washer. Is there any benefit to using the insulator in this situation?
Electronic – Mica Insulator for TO-220 Grounded Heat Sink
heatsinktransistors
Related Topic
- Electronic – Heatsink or IC: how to determine root cause of overtemp
- Electronic – TO-220 rectangular washers
- Electronic – Leakage current to heat sink
- Electronic – Modelling heat transfer from Power LED to metal bar
- Electronic – Heat sinking ideas for an HZIP package
- Electronic – Electrical insulation resistance of TO-220 package with SIL pad and plastic shoulder washer
- Electronic – Regulator/heatsink heating up even though load is only 50% of regulator Imax
Best Answer
If the bolt isn't insulated then it will (electrically) connect the TO220 pad to the heatsink, so the mica insulator serves no purpose. You'll get better heat transfer to the heatsink if you remove the insulator.