Electronic – Why is maximum flux attained in transformer when off load

electromagnetismtransformer

Can anyone explain to me why the maximum flux in a transformer is attained when off load?

What happens to the flux when on load? Are the flux from the secondary load current and primary load current just leaking out into space? Or are the magnetic particles somehow being canceled or destroyed? Does anyone have an answer instead of just pointing at conditional math equations that don't explain anything?

Another user claimed the load current flux somehow cancels the primary current flux, but this is inadequate as "canceling" doesn't explain what's happening. Two opposing fluxes should both contribute to a lowered permeability of material. If they don't, then why is this? One would have to conclude that the particles or virtual particles (whatever a magnetic field consists of) are literally being transformed/destroyed/significantly altered or something drastic.

The simplest conclusion is that the vast majority of flux generated while a transformer is loaded should be leaking out into space around the core. But I haven't heard anyone say this. I've certainly never run the experiment myself. Does anyone know if the magnetic field around the outside of a core goes sky high when you put it on load?

Best Answer

Look at the following scenarios and then it should be clearer why maximum transformer flux happens when off-load: -

enter image description here

The above are perfect idealizations of inductors and transformers. And if you are having problems with any of the steps then maybe someone else can do this question some justice.

Why is flux greatest when off-load - if there were no-losses in the windings (R or leakage inductance) then off-load or on-load the flux in the core remains exactly the same (scenario 4). But, because the secondary current causes small volt-drops in the primary winding, the voltage that is able to magnetize the core is slightly reduced thus the flux in the core is slightly reduced and the core is less able to saturate.

The permeability of the material (when not close to saturating) is determined by the physical properties of the material and not the opposing fluxes in primary and secondary due to load current.

The vast majority of flux does not leak into space around the core - it is contained within the core and cancels out to zero for load-currents leaving what was originally there - the magnetizing flux.

When a turns ratio is applied ampere-turns from primary might be 1 x 10 whereas on the secondary (for 10:1 turns ratio) they will be 10 x 1 - ampere-turns drive flux and these cancel out just the same as a 1:1 transformer.

Here is the link to the question posed by Jim related to this one.

Lenz's Law Lenz's law says

"An induced current creates a magnetic field that opposes the changing flux that initially gave rise to the induced current".

Bar magnets This is not the same in bar magnets held N-N and S-S. In Bar magnets (held steady wrt each other) there is no induction and therefore only a force exists and I think this is to do with Newtons 3rd Law?

Twisted pair cable Also think about twisted pair cable - there is no net flux emanating beyond a small distance. of course there are very local fluxes around each wire but these cancel at a very short distance.